Please refer to the Monitoring Settings 1 (Automatic Alarm) section of this manual for more information.ġ0 – “Purge Guard Opened” – Indicates that the injection unit cover is open.
Check the ejector position as well as the relevant potentiometer.ĩ – “Inject Cushion Error” – Indicates the injection parameters during the last production cycle have been outside the preset limits. Please refer to the Monitoring Settings 1 (Automatic Alarm) section of this manual for more information.Ĩ – “Eject Position Error” – Indicates an ejector position problem. In case of low temperature make sure the hydraulic motor is turned on and wait until the motor has warmed up the hydraulic oil sufficiently.Ħ – “Cycle Time Exceeded” – Indicates the production cycle time during the last cycle has been outside the preset limits. In case of overheating make sure the cooling system is turned on. Check the parameter settings and adjust if necessary. Over” – Indicates the hydraulic oil temperature is too low or too high. Release the Emergency key if necessary to resume machine operation.ĥ – “Oil Temp. Key” – Indicates the machine has been stopped as a result of pressing either the Manual key or the Emergency button. Please refer to the injection moulding Machine Control Panel Keys section of this manual for additional information.Ĥ – “Off Man./Emerg. Please refer to the Machine Control Panel Keys section of this manual for additional information.ģ – “Please Open Door” – Prompt in Semi-auto mode to open the door at the end of the production cycle.
Please refer to the Temperature Control section of this manual for additional information.Ģ – “Please Close Door” – Prompt in Semi-auto mode to close the door to start the next production cycle. Check the settings and current temperature. Please refer to the Error Messages Display Screen section for more information.ġ – “Temperature Error” – Indicates a barrel heating temperature problem/possible malfunction. In case of multiple alarms this screen allows you to verify any error/alarm messages the status bar might not have displayed. In case of multiple alarms the status bar will display the most important alarm.įor a more detailed description and analysis of the error(s) that caused the alarm you can switch to the Error Messages Display Screen by pressing the (F6) Alarm key. You can see the alarm messages regardless of the screen you are currently using. In case of an error the corresponding alarm message will be displayed in the status bar in the lower left part of your screen just above the F1 – F10 keys (please refer to the Overview section for exact location of the status bar).
Light converse manual series#